← Browse · Bridgmanite

Bridgmanite

MgSiO3 with 5 mol% Al2O3

third-order Birch-Murnaghan · Original · 1999

Why this differs from similar rows?

Table 3, Run 2 of the in situ P-V-T XRD experiment; ambient V0 fixed to the measured Run 2 unit-cell volume (163.184 A3), distinct from Runs 1 and 3.

V₀
163.184
ų
Unit cell
K₀
232
GPa
Isothermal
K′
4
dimensionless

Volume (V₀)

Value Unit Basis Z
163.184 ų Unit cell

Reported value and unit are preserved as extracted. Z (formula units per cell) is not stored yet, so molar ↔ ų/f.u. conversion is not applied automatically.

Composition

OxideMolar
MgO1
SiO21

Formula: MgSiO3

Conditions & method

Tref
300 K
Pref
Structure
orthorhombic perovskite (Pbnm/Pnma)
Method
experiment (XRD / DAC / multianvil compression)
in situ P-V X-ray diffraction (multi-anvil press, NaCl medium)
Sample
Al-Pv, Run 2

Source

Paper
Thermal Equation of State of Aluminum-Enriched Silicate Perovskite
Authors
Jianzhong Zhang; Donald J. Weidner
DOI
10.1126/science.284.5415.782
Year
1999
Journal
Science
Origin
Original (measured or fitted in the source paper)

Evidence from the paper

Table 3: Al-Pv Run 2: K_{0,T} = 232(1) GPa; 'In all studies, the pressure derivative, K_0', is fixed at 4. Ambient unit-cell volume, V_0, was fixed in the data reduction of this study.' Table 1, Run 2 (beginning of run): V = 163.184(76) ų.

Additional notes

beta a x1e3 GPa-1
1.40(2)
beta b x1e3 GPa-1
1.19(2)
beta c x1e3 GPa-1
1.45(3)
V0 note
Table 1 also lists end-of-run volume 163.202(92) ų for Run 2; text quotes K_{0,T} range 232(2) to 236(2) GPa