← Browse · Bridgmanite

Bridgmanite

MgSiO3

third-order Birch-Murnaghan · Original · 2009

Why this differs from similar rows?

Primary free fit to P-V-T XRD data (19-53 GPa, 300-2300 K) yielding both K_T0 and K'_T0; sibling row instead fixes K_T0 to 253 GPa and refits only K'_T0.

V₀
Unknown basis
K₀
256
GPa
Isothermal
K′
3.800
dimensionless

Volume (V₀)

Value Unit Basis Z
Unknown basis

Reported value and unit are preserved as extracted. Z (formula units per cell) is not stored yet, so molar ↔ ų/f.u. conversion is not applied automatically.

Composition

OxideMolar
MgO1
SiO21

Formula: MgSiO3

Conditions & method

Tref
300 K
Pref
Structure
orthorhombic perovskite (Pbnm/Pnma)
Method
experiment (XRD / DAC / multianvil compression)
in situ energy-dispersive X-ray diffraction in Kawai-type multi-anvil apparatus (WC and SD anvils), SPring-8 BL04B1
Sample
MgSiO3 perovskite synthesized in situ from enstatite/forsterite+MgO starting materials

Source

Paper
P‐V‐T relations of MgSiO3 perovskite determined by in situ X‐ray diffraction us…
Authors
Tomoo Katsura; Sho Yokoshi; Kazuaki Kawabe; Anton Shatskiy; Geeth Manthilake; Shuangmeng Zhai; Hiroshi Fukui; H. A. Chamathni I. Hegoda; Takashi Yoshino; Daisuke Yamazaki; Takuya Matsuzaki; Akira Yoneda; Eiji Ito; Mitsuhiro Sugita; Naotaka Tomioka; Kenji Hagiya; Akifumi Nozawa; Ken‐ichi Funakoshi
DOI
10.1029/2008gl035658
Year
2009
Journal
Geophysical Research Letters
Origin
Original (measured or fitted in the source paper)

Evidence from the paper

The obtained volume data at high pressure and ambient temperature, V_P,0, were fitted to the third-order Birch-Murnaghan equation of state ... We obtained K_T0 = 256(2) GPa and K'_T0 = 3.8(2).

Additional notes

ambient cell parameters
a0 = 4.7769(2), b0 = 4.9298(2), c0 = 6.8956(3) Å
theta0
1030 K (fixed, from Akaogi and Ito [1993])
gamma0
2.6(1)
q
1.7(1)
dKT dT P
-0.035(2) GPa/K (high-temperature Birch-Murnaghan fit)
delta T
6.5(5)
alpha0
2.6(1)x10^-5 + 1.0(1)x10^-8 (T - 300)/K
pressure range
19 to 53 GPa
temperature range
300 to 2300 K
pressure scales
MgO scales of Matsui et al. [2000] and Speziale et al. [2001]
thermal eos
Mie-Grüneisen-Debye equation of state used for P-V-T fitting